Solis NO-GRID (Alarm 1015) — No Grid Voltage Detected

What it means: The inverter cannot detect a usable AC supply at its grid terminals, so it will not connect or export. Solis logs it as alarm 1015 and titles their own service article "NO-GRID (AC MCB Tripping)", because a tripped AC breaker is the most common cause after an ordinary outage. On a grid-tied Solis this is usually the inverter reporting the state of the world correctly, not a fault in the inverter.

Why does Solis show NO-GRID?

The Pakistan factor

In Pakistan NO-GRID is the single most-seen entry in a Solis alarm log and most of those entries are simply load shedding being recorded faithfully — one line per outage. Treat the log as a record, not an alarm, unless it appears while the rest of the street has power. The two cases that do matter here are both installer-side. First, AC breakers on Pakistani installs are frequently chosen by rule of thumb rather than by the inverter's rated output current, and an under-rated breaker on a system that runs at full output through a Punjab summer afternoon will nuisance-trip; the fix is the right breaker, never a bigger one chosen at random. Second, the sheer number of grid interruptions here means AC breakers see far more operations than they would on a stable supply, and a breaker that has been cycled thousands of times eventually stops holding. Both are cheap fixes — neither is a reason to touch the inverter.

How to fix it (safe to try yourself)

  1. First, check whether anyone else has power. If it is a load-shedding slot or a neighbourhood outage, NO-GRID is the expected reading and there is nothing to fix.
  2. Understand what your model does during an outage. A grid-tied Solis is required to shut down when the grid goes away — that anti-islanding behaviour protects linesmen working on the dead feeder. If you have a grid-tied unit rather than a hybrid, having no power during an outage is the design, not a failure, and no setting changes it.
  3. Look at the AC MCB or isolator feeding the inverter. If it is visibly tripped, you may switch it back on once.
  4. If it trips again straight away, stop. Do not keep resetting it. A breaker that trips immediately is reporting a real fault downstream of it, and repeatedly forcing it back on is how a wiring fault becomes a fire. Leave it off and call your installer.
  5. If the grid is present at your meter and the breaker is on but the inverter still says NO-GRID, hand it to your installer. Solis's checklist for them is to verify the AC breaker rating against the system size, replace a suspect breaker, confirm AC cable connections and wire sequence at the connector, measure line-to-neutral, line-to-earth and neutral-to-earth voltages at the inverter's AC gland, and check for loose contacts through to the meter.
  6. Ask them to confirm the Grid ON/OFF setting is set to ON. It sits in the technician-only Advanced Settings menu and is occasionally left off after a site visit.
  7. Do not open the inverter or the AC distribution box yourself, and do not attempt to bypass the breaker to "test" whether the inverter works. If the alarm survives a competent installer's checks, it goes to the Solis service centre with the model, serial number, firmware version and installation date.

References