Victron EM24 Meter: Ethernet & RS485 Setup

Updated 6 September 2026 · By SolarNevs Research Desk, Dealer surveys + verified sources · 1 source · Method ↗

Victron EM24 Meter: Ethernet & RS485 Setup — SolarNevs spec card

Key Takeaways

  • The Victron EM24 Ethernet is a standard device to measure the power and energy of a 3-phase application. Its data will be displayed on a GX device and our VRM portal..
  • High-speed ESS grid control: As a Grid meter and used as control input for an ESS System..
  • Solar generation tracking: To measure the output of a PV Inverter..
  • Backup power metering: To measure the output of a AC Genset..
  • Sub-circuit power logging: As an AC meter to measure a dedicated AC load circuit..
  • Direct LAN network connectivity: A wired ethernet connection to the local network in such a way that the GX device can reach it..
  • Venus OS software role selection: The configuration option of either Grid Meter, PV Inverter, Generator or AC Meter is set in the GX device..
  • Voltage sensing protection rule: Note that wherever the word "Fuse" appears in the diagrams, a 315 mA fuse should be used, if required by local law..
  • Solar current direction wiring rule: When used to measure a PV Inverter, terminals 1, 4 and 7 should face the PV inverter to ensure correct direction of current and power..
  • Single-phase jumpered topology: Single-phase, single function EM24 connected as a single-phase, single function grid meter.

Ethernet Modbus TCP Architecture & System Operating Roles

The EM24 Ethernet connects directly to local area networks, streaming revenue-grade 3-phase electrical data to Cerbo GX and Ekrano GX controllers via Modbus TCP without requiring USB-to-RS485 adapters.

The Victron EM24 Energy Meter is a 3-phase revenue-grade energy meter with Ethernet Modbus TCP, supporting operating roles as a Grid Meter (ESS), PV Inverter meter, Genset meter, or AC Sub-Circuit Load meter:

  • AC Phase Terminals: 3-Phase Direct In, Term 1,4,7 to PV, Single-Phase Jumper, Direct Line Meter.
  • Voltage Fusing: 315 mA Fuses, Voltage Reference, Local Law Compl., Safety Fusing.
  • Network Link: Ethernet LAN, Modbus TCP, Cerbo GX / OS, VRM Portal.

Installation Rules & Electrical Wiring

  1. Grid Meter Role: Land incoming utility feeds ensuring The configuration option of either Grid Meter, PV Inverter, Generator or AC Meter is set in the GX device. operating As a Grid meter and used as control input for an ESS System..
  2. PV Inverter Sizing: Wire terminals so that When used to measure a PV Inverter, terminals 1, 4 and 7 should face the PV inverter to ensure correct direction of current and power..
  3. Voltage Protection: Protect sensing circuits ensuring Note that wherever the word "Fuse" appears in the diagrams, a 315 mA fuse should be used, if required by local law..

Local Area Network Interfacing & System Functions

The EM24 integrates seamlessly into the Victron ecosystem:

  • Wired Ethernet Connection: Establishes A wired ethernet connection to the local network in such a way that the GX device can reach it..
  • Multi-Role Functionality: Operates To measure the output of a PV Inverter., To measure the output of a AC Genset., or As an AC meter to measure a dedicated AC load circuit..
  • Single-Phase Flexibility: Configures as Single-phase, single function EM24 connected as a single-phase, single function grid meter.
  • Comprehensive Capability: Operates reliably because The Victron EM24 Ethernet is a standard device to measure the power and energy of a 3-phase application. Its data will be displayed on a GX device and our VRM portal..

Technical Specifications & Sizing Summary

Parameter

Engineering Rating

Design Significance

Primary Meter Function

The Victron EM24 Ethernet is a standard device to measure the power and energy of a 3-phase application. Its data will be displayed on a GX device and our VRM portal.

High-precision 3-phase grid and generation measurement

ESS Grid Control Role

As a Grid meter and used as control input for an ESS System.

Enables dynamic zero-export and phase balancing in ESS

Solar PV Metering Role

To measure the output of a PV Inverter.

Dedicated metering of AC-coupled solar generation

Generator Metering Role

To measure the output of a AC Genset.

Real-time generator output and energy logging

Dedicated Subcircuit Role

As an AC meter to measure a dedicated AC load circuit.

Sub-metering of EV chargers and heavy machinery

Network Interface Link

A wired ethernet connection to the local network in such a way that the GX device can reach it.

Direct LAN Modbus TCP connection without USB converters

Software Role Selection

The configuration option of either Grid Meter, PV Inverter, Generator or AC Meter is set in the GX device.

Flexible operating role assignment in Venus OS

Voltage Sense Protection

Note that wherever the word "Fuse" appears in the diagrams, a 315 mA fuse should be used, if required by local law.

Protects unmetered voltage reference lines

PV Current Orientation

When used to measure a PV Inverter, terminals 1, 4 and 7 should face the PV inverter to ensure correct direction of current and power.

Ensures accurate solar energy direction logging

Single-Phase Operation

Single-phase, single function EM24 connected as a single-phase, single function grid meter

Flexible wiring topology for single-phase installations